Ante-mortem measurement of spleen size may be valuable to understand and study hemodynamic changes during exercise and in clinical determination of splenomegaly. The hypotheses were that spleen volume can be calculated from transcutaneous ultrasonographic measurements in live standing horses; and that the spleen volume is proportional to blood volume, maximal under the influence of detomidine and minimal under the influence of epinephrine. Eight donated horses free of splenic disease were studied. Ultrasonographic spleen volume and Evans blue dye-dilution blood volume were measured before (baseline) and after intravenous administration of detomidine and epinephrine (separately). Spleen volume was calculated using a standard ellipsoid formula (VOLstandard) and with the formula modified for the unique shape of the equine spleen (VOLmodified). Horses were euthanised using pentobarbital sodium, spleens removed immediately and measurements repeated on the removed spleen. Descriptive statistics, correlation and regression analysis were performed. Mean VOLstandard was 31.4±9.8 litre at baseline, 34.0±10.5 litre after detomidine, and 5.4±3.1 litre after epinephrine. VOLmodified was 25.1±9.1 litre at baseline, 27.4±9.6 litre after detomidine, and 4.2±2.4 litre after epinephrine. Post-mortem spleen volume was 14.1±4.6 litre and was correlated with VOLstandard (r=0.86, P=0.006) and VOLmodified (r=0.87, P=0.004). Blood volume was correlated with VOLstandard (r=0.81, P=0.014) and VOLmodified (r=0.78, P=0.02). Packed cell volume after epinephrine was correlated with VOLstandard (r=0.95, P<0.001) and VOLmodified (r=0.96, P<0.001). When compared to baseline, spleen volume was smaller after epinephrine (P=0.009) but not larger after detomidine (P=0.12). Blood volume after epinephrine was larger than after detomidine (P=0.009). The study demonstrated that splenic size, under various pharmacological influences, can be calculated from ultrasonographic measurements in the live standing horse. Packed cell volume after epinephrine was the best indicator of spleen volume.
Purchase
Buy instant access (PDF download and unlimited online access):
Institutional Login
Log in with Open Athens, Shibboleth, or your institutional credentials
Personal login
Log in with your brill.com account
Blikslager, A.T. and Wilson, D.A., 1999. Stomach and spleen. In: Auer, J.A. and Stick, J.A. (eds.) Equine Surgery, 3rd ed. W.B. Saunders, Philadelphia, PA, USA, pp. 378-386.
Equine Surgery , () 378 -386 .
Carlson, G.P., 2002. Equine infectious anemia. In: Bradford, B.P. (ed.) Large animal internal medicine, 3rd ed. Mosby, St Louis, MO, USA, pp. 1056-1057.
Large animal internal medicine , () 1056 -1057 .
Davis, J.L., 1986. Hemodynamics in splenectomized ponies during exertion. Phd. thesis. University of Illinois at Urbana-Champaign, IL, USA.
Hemodynamics in splenectomized ponies during exertion. Phd. thesis , ().
Farrow, C.S., 2006. Liver and spleen. In: Veterinary diagnostic imaging: the horse. Elsevier Mosby, St. Louis, MO, USA, pp. 544-547.
Veterinary diagnostic imaging: the horse , () 544 -547 .
Hanson, C.M., Kline, K.H., Foreman, J.H., Frey, L.P. and Cooper, S.M., 1995. Heart and spleen mass related to blood parameter changes after epinephrine injection. Equine Veterinary Journal Suppl. 18: 113-116.
'Heart and spleen mass related to blood parameter changes after epinephrine injection ' () 18 Equine Veterinary Journal Suppl. : 113 -116 .
Hardy, J., Bednarski, R.M. and Biller, D.S., 1994. Effect of phenylephrine on hemodynamics and splenic dimensions in horses. American Journal of Veterinary Research 55: 1570-1578.
'Effect of phenylephrine on hemodynamics and splenic dimensions in horses ' () 55 American Journal of Veterinary Research : 1570 -1578 .
Henderson, J.M., Heymsfield, S.B., Horowitz, J. and Kutner, M.H., 1981. Measurement of liver and spleen volume by computed tomography. Radiology 141: 525-527.
'Measurement of liver and spleen volume by computed tomography ' () 141 Radiology : 525 -527 .
Ishibashi, H., Higuchi, N., Shimamura, R., Hirata, Y., Kudo, J. and Niho, Y., 1991. Sonographic assessment and grading of spleen size. Journal of Clinical Ultrasound 19: 21-25.
'Sonographic assessment and grading of spleen size ' () 19 Journal of Clinical Ultrasound : 21 -25 .
Kline, H. and Foreman, J.H., 1991. Heart and spleen weights as a function of breeds and somatotype. In: Persson, S.G.B., Lindholm, A. and Jeffcott, L.B. (eds.) Equine exercise physiology, vol. 3. ICEEP Publications, Davis, CA, USA, pp. 17-21.
Equine exercise physiology , () 17 -21 .
Koga, T., 1979. Correlation between sectional area of the spleen by ultrasonic tomography and actual volume of the removed spleen. Journal of Clinical Ultrasound 7: 119-120.
'Correlation between sectional area of the spleen by ultrasonic tomography and actual volume of the removed spleen ' () 7 Journal of Clinical Ultrasound : 119 -120 .
Lamb, P.M., Lund, A., Kanagasabay, R.R., Martin, A., Webb, J.A. and Reznek, R.H., 2002. Spleen size: how well do linear ultrasound measurements correlate with three-dimensional CT volume assessments? British Journal of Radiology 75: 573-577.
'Spleen size: how well do linear ultrasound measurements correlate with three-dimensional CT volume assessments? ' () 75 British Journal of Radiology : 573 -577 .
Loftus, W.K. and Metreweli, C., 1998. Ultrasound assessment of mild splenomegaly: spleen/kidney ratio. Pediatric Radiology 28: 98-100.
'Ultrasound assessment of mild splenomegaly: spleen/kidney ratio ' () 28 Pediatric Radiology : 98 -100 .
Loftus, W.K., Chow, L.T. and Metreweli, C., 1999. Sonographic measurement of splenic length: correlation with measurement at autopsy. Journal of Clinical Ultrasound 27: 71-74.
'Sonographic measurement of splenic length: correlation with measurement at autopsy ' () 27 Journal of Clinical Ultrasound : 71 -74 .
McKeever, K.H., Hinchcliff, K.W., Reed, S.M. and Robertson, J.T., 1993. Role of decreased plasma volume in hematocrit in alterations during incremental treadmill exercise in horses. American Journal of Physiology - Regulatory, Integrative and Comparative Physiology 265: R404-R408.
'Role of decreased plasma volume in hematocrit in alterations during incremental treadmill exercise in horses ' () 265 American Journal of Physiology - Regulatory, Integrative and Comparative Physiology : R404 -R408 .
O'Brien, R.T., Waller III, K.R. and Osgood, T.L., 2004. Sonographic features of drug-induced splenic congestion. Veterinary Radiology and Ultrasound 45: 225-227.
'Sonographic features of drug-induced splenic congestion ' () 45 Veterinary Radiology and Ultrasound : 225 -227 .
Persson, S.G.B., 1975. The circulatory significance of the splenic red cell pool. In: Kitchen, H. and Krehbiel, J.D. (eds.) Proceedings of 1st International Symposium on Equine Hematology. University Microfilms, Ann Arbor, MI, USA, pp. 303-310.
Proceedings of 1st International Symposium on Equine Hematology , () 303 -310 .
Persson, S.G.B., 1967. On blood volume and working capacity in horses. Studies of methodology and physiological and pathological variations. Acta Veterinaria Scandinavica 19 Suppl.: 1-189.
'On blood volume and working capacity in horses. Studies of methodology and physiological and pathological variations ' () 19 Acta Veterinaria Scandinavica : 1 -189 .
Reef, V.B., 1998. Adult abdominal ultrasonography. In: Reef, V.B. (ed.) Equine diagnostic ultrasound. W.B. Saunders, Philadelphia, PA, USA, pp. 273-363.
Equine diagnostic ultrasound , () 273 -363 .
Savage, C.J., 1999. Diseases of the spleen. In: Colahan, P.T. (ed.) Equine medicine and surgery, 5th ed. Mosby, St. Louis, MO, USA, pp. 2058-2062.
Equine medicine and surgery , () 2058 -2062 .
Sellon, D.C., 2004. Disorders of the hematopoietic system. In: Bayly, W., Reed, S.M. and Sellon, D.C. (eds.) Equine internal medicine. W.B. Saunders, Philadelphia, PA, USA, pp. 721-769.
Equine internal medicine , () 721 -769 .
Sisson, S. and Grossman, J.O., 1975. Anatomy of the domestic animals, 5th ed. W.B. Saunders, Philadelphia, PA, USA, pp. 630-632.
Anatomy of the domestic animals , () 630 -632 .
Steel, J.D. and Whitlock, L.E., 1960. Observations on the haematology of Thoroughbred and Standardbred horses in training and racing. Austalian Veterinary Journal 36: 136-142.
'Observations on the haematology of Thoroughbred and Standardbred horses in training and racing ' () 36 Austalian Veterinary Journal : 136 -142 .
Vischer, C.M., Foreman, J.H. and Constable, P.D., 1999. Hemodynamic effects of thyroidectomy in sedentary horses. American Journal of Veterinary Research 60: 14-21.
'Hemodynamic effects of thyroidectomy in sedentary horses ' () 60 American Journal of Veterinary Research : 14 -21 .
Wilson, D.V., Evans, A.T., Carpenter, R.A. and Mullineaux, D.R., 2004. The effect of four anesthetic protocols on splenic size in dogs. Veterinary Anaesthesia and Analgesia 31: 102-108.
'The effect of four anesthetic protocols on splenic size in dogs ' () 31 Veterinary Anaesthesia and Analgesia : 102 -108 .
Yetter, E.M., Acosta, K.B., Olson, M.C. and Blundell, K., 2003. Estimating splenic volume: sonographic measurements correlated with helical CT determination. American Journal of Roentgenology 181: 1615-1620.
'Estimating splenic volume: sonographic measurements correlated with helical CT determination ' () 181 American Journal of Roentgenology : 1615 -1620 .
Young, L.E., Marlin, D.J., Deaton, C., Brown-Feltner, H., Roberts, C.A. and Wood, J.L., 1999. Relationship between VO2max, heart score and echocardiographic measurements obtained at rest and immediately following maximal exercise in Thoroughbred horses. Equine Veterinary Journal Suppl. 30: 190-194.
'Relationship between VO2max, heart score and echocardiographic measurements obtained at rest and immediately following maximal exercise in Thoroughbred horses ' () 30 Equine Veterinary Journal Suppl. : 190 -194 .
Young, L.E., Marlin, D.J., Deaton, C., Brown-Feltner, H., Roberts, C.A. and Wood, J.L., 2002. Heart size estimated by echocardiography correlates with maximal oxygen uptake. Equine Veterinary Journal Suppl. 34: 467-471.
'Heart size estimated by echocardiography correlates with maximal oxygen uptake ' () 34 Equine Veterinary Journal Suppl. : 467 -471 .
Young, L.E., Rogers, K. and Wood, J.L., 2005. Left ventricular size and systolic function in Thoroughbred racehorses and their relationships to race performance. Journal of Applied Physiology 99: 1278-1285.
'Left ventricular size and systolic function in Thoroughbred racehorses and their relationships to race performance ' () 99 Journal of Applied Physiology : 1278 -1285 .
| All Time | Past 365 days | Past 30 Days | |
|---|---|---|---|
| Abstract Views | 380 | 134 | 12 |
| Full Text Views | 25 | 4 | 0 |
| PDF Views & Downloads | 43 | 11 | 0 |
Ante-mortem measurement of spleen size may be valuable to understand and study hemodynamic changes during exercise and in clinical determination of splenomegaly. The hypotheses were that spleen volume can be calculated from transcutaneous ultrasonographic measurements in live standing horses; and that the spleen volume is proportional to blood volume, maximal under the influence of detomidine and minimal under the influence of epinephrine. Eight donated horses free of splenic disease were studied. Ultrasonographic spleen volume and Evans blue dye-dilution blood volume were measured before (baseline) and after intravenous administration of detomidine and epinephrine (separately). Spleen volume was calculated using a standard ellipsoid formula (VOLstandard) and with the formula modified for the unique shape of the equine spleen (VOLmodified). Horses were euthanised using pentobarbital sodium, spleens removed immediately and measurements repeated on the removed spleen. Descriptive statistics, correlation and regression analysis were performed. Mean VOLstandard was 31.4±9.8 litre at baseline, 34.0±10.5 litre after detomidine, and 5.4±3.1 litre after epinephrine. VOLmodified was 25.1±9.1 litre at baseline, 27.4±9.6 litre after detomidine, and 4.2±2.4 litre after epinephrine. Post-mortem spleen volume was 14.1±4.6 litre and was correlated with VOLstandard (r=0.86, P=0.006) and VOLmodified (r=0.87, P=0.004). Blood volume was correlated with VOLstandard (r=0.81, P=0.014) and VOLmodified (r=0.78, P=0.02). Packed cell volume after epinephrine was correlated with VOLstandard (r=0.95, P<0.001) and VOLmodified (r=0.96, P<0.001). When compared to baseline, spleen volume was smaller after epinephrine (P=0.009) but not larger after detomidine (P=0.12). Blood volume after epinephrine was larger than after detomidine (P=0.009). The study demonstrated that splenic size, under various pharmacological influences, can be calculated from ultrasonographic measurements in the live standing horse. Packed cell volume after epinephrine was the best indicator of spleen volume.
| All Time | Past 365 days | Past 30 Days | |
|---|---|---|---|
| Abstract Views | 380 | 134 | 12 |
| Full Text Views | 25 | 4 | 0 |
| PDF Views & Downloads | 43 | 11 | 0 |